Safe installation methods for buckle type steel pipe scaffolding and high formwork construction

For the coiled steel pipe fastener scaffold, the special construction scheme must be prepared to specify the height of the scaffold, load standards, support conditions, wall connecting pieces and slant support layout, and can be implemented only after approval.

The foundation of the frame must be flat and solid, and the bottom of the pole must not be suspended or loose.

The connection adopts a buckle node, with the pin self-locking and hammering to the position, and the sinking amount shall not exceed the specified limit to ensure the reliability of the node.

The pedals should be fully covered, and protective railings and toe boards should be installed around the perimeter.

doka floor prop nut

Safety nets or steel mesh should be erected to prevent falling from heights and objects.

The structural system of the frame should be complete, including upright poles, horizontal poles, longitudinal and transverse diagonal braces or diagonal poles, connecting wall components, etc.

The components should not be mixed arbitrarily, and the specifications, spacing, and step distance of various types of poles must meet the requirements of the specifications.

During use, the structural system must not be changed arbitrarily, and dismantling must be organized according to the plan.

During use, the deformation and connection fastening of nodes, fasteners, and frames should be regularly checked.

.